L5300 and L5200 On-Demand Calibrator (ODC) Instructions

Learn how to calibrate your L5300 or L5200 meter with the On-Demand Calibrator (ODC) with these easy-to-follow steps! This video provides a step-by-step guide to ensure accurate calibration, from matching serial numbers to properly seating your meter on the ODC. Follow along to keep your moisture measurements precise and reliable.

Instructions:

  • Make sure the serial number on your On-Demand Calibrator (ODC) matches the serial number on your meter. The serial number can be found on the battery door cover.
  • Place the ODC on its legs on a non-metallic surface.
  • Turn the meter on, then use the button and jog pad to select the CALIBRATION menu item.
  • Place the meter on the ODC, correctly “seating” the meter sensor pad firmly in the recessed area of the ODC.
    IMPORTANT: Failure to correctly and firmly “seat” the sensor pad in the recessed area will cause an inaccurate calibration.
  • Verify the meter is seated correctly by moving the meter slightly front to back and then side to side.
  • Apply light downward pressure and press the button 3 times. The meter LCD will flash “Reading” which indicates it’s going through the calibration process.
  • When the calibration procedure is completed, the meter will display “Lift Meter in Air for 5 Seconds.” Immediately remove the meter from the ODC and hold the meter in the air for approximately 5 seconds until the words “Calibration Done” appear on the display.
  • Press the button to save the calibration and return to the menu.

Follow these instructions to verify the calibration of your L5300 or L5200 meter and recalibrate it if needed. If you use an L722 Lumber Stack Probe with your L5300, follow the additional instructions below to verify the probe’s calibration and arrange recalibration if needed.

Verify the L5300/L5200 Meter

  1. Disconnect the L722 Stack Probe, if connected to a L5300. The meter cannot begin its calibration routine while the probe is connected.
  2. Check L5200/L5300 meter reading. Select Douglas Fir (SG .48) and place the meter on its matching On-Demand Calibrator (ODC). Compare the reading with the reference value on the ODC label.
  3. Recalibrate if needed. If the reading differs from the reference value by more than ±1 percentage point of moisture content, select CALIBRATION from the main menu and follow the on-screen prompts. Calibration instructions are also provided on the back of the ODC.

If Recalibration Fails

The meter displays an error and recovery options. Follow the on-screen recovery instructions. A failed recalibration attempt does not immediately turn the meter off; the normal Auto Off setting still applies. After repeated failures, an option to restore factory calibration may appear.

If you cannot recalibrate your meter after a factory reset, contact Wagner Meters to determine whether it needs to be sent in for service.

Verify the L722 Lumber Stack Probe

The L5300 ODC can verify the calibration of the L722 Lumber Stack Probe, but it cannot recalibrate the probe. Recalibrating the meter does not recalibrate the probe.

First, complete steps 1–3 under Verify the L5300/L5200 Meter. Then, follow the steps below to verify your L722 Stack Probe.

  1. Connect the probe. Connect the L722 Stack Probe to your L5300 meter.
  2. Position the probe and take a reading. With Douglas Fir (SG .48) still selected, place the L722 on the ODC with its sensor plate seated inside the recess of the ODC block. Apply light, firm pressure to the L722 head while taking the reading to keep the sensor plate securely seated.
    A reading is not valid if the sensor plate is outside the recess or is not held firmly in place.
  3. Check the reading. Compare the reading with the L722 target value of 22.3% ±1 percentage point of moisture content, an acceptable range of 21.3% to 23.3%.
  4. Send the probe for recalibration if needed. If the reading is outside the acceptable range, send your L722 Stack Probe to Wagner Meters for recalibration. Scan the QR code below or visit the link to complete the Wagner Meters repair form and view shipping instructions.

NIST-traceable meter ODC blocks are also available for documented verification against a national reference.