Test Method |
|
Calcium Chloride Moisture Vapor |
|
Emission Rate Testing |
|
ASTM F1869 |
|
|
Rapid RH® 4.0 |
|
with Touch-n-Sense Technology |
|
ASTM F2170 |
|
|
Materials Needed |
MVER kits; surface grinder, vacuum, scrapers, precision gram scale |
Rapid RH Easy Reader and Smart Sensors; 3/4-in drill bit and drill; brush and vacuum
|
|
Prepare test locations |
|
Clean the floor: scrape and grind to remove debris and make a clean surface |
|
1 hour 5 minutes |
|
--- |
|
Prepare the test |
|
Check integrity of sealed calcium chloride packages. Open packages, weigh dishes, record weight, date and time. |
|
1 hour 5 minutes |
|
--- |
|
Place the test |
|
Remove tape from dishes, remove cover and invert, place on concrete, install domes, press to seal, check if seal is airtight. |
|
1 hour 5 minutes |
|
|
Drill Holes |
|
Vacuum dust |
|
Insert |
|
|
|
1 hour 5 minutes |
|
|
Protect the test |
|
Install CAUTION tape, build wooden frame, or otherwise mark to avoid damage |
|
2 hours |
|
--- |
|
Obtain results(after required 72 hours)
|
|
Check air tightness of seals; cut open domes, retrieve dishes, invert covers, re-tape, weigh dishes, and calculate results. |
|
2 hours 10 minutes |
|
|
Insert Easy Reader. |
|
|
|
|
|
3.5 minutes |
|
|
Cleanup |
|
Scrape sealant from concrete; dispose domes, dishes, used calcium chloride, sealant |
|
20 minutes |
|
|
Trowel one tablespoon patching compound into each hole. |
|
7 minutes |
|
|
Material costs for 13 tests |
$147.95 (13 kits) |
$600 (includes 15 Smart Sensors + 1 Easy Reader) |
|
Total time required to obtain readings on first 13 tests |
72 hours |
2 hours |
|
Total time required to obtain additional testing data |
78.5 hours |
10 minutes |
|
Material costs to obtain additional testing data |
$147.95 (13 kits) |
--- |
|
Total Time |
158 hours 15 minutes |
3 hours 25.5 minutes |
|
|